Aluminum Gas Dry Hearth Melting Furnace GM-D-2600

  • Request More Info
  • Make an Offer
  • Schedule Test Drive
  • Email to a Friend
  • Financial Form
  • Print

The dry hearth charging chamber has no molten metal in it thus it reduces the dangers of metal splash and prevents temperature drop caused by the addition of cold ingots or scrap to the metal bath. The charging chamber is angled down and as the metal melts it runs into the metal bath.

  • Advance PLC control which is easy to learn and operate
  • Advanced burner system which reduces generation of oxides
  • Charging door on back
  • Cleanout door on left side
  • Dual temperature control (melting and holding burners)
  • Fully automatic operation
  • High quality cast refractory lining
  • High thermal efficiency
  • Large charging rear door
  • Large side maintenance door
  • Low metal burn rate of less than 1.5%
  • Solid frame structure which is easy to clean and maintain
  • Temperature alarm
  • Temperature control accuracy within 5° C
Item US Standard Metric
Holding Capacity 2600 lbs 1200 kg
Melting Capacity 865 lbs/h 390 kg/h
Rated Power (melting burner) 793,133 BTU/h 200,000 kCal/h
Rated Power (holding burner) 594,850 BTU/h 150,000 kCal/h
Total Rated Power 1,387,983 BTU/h 350,000 kCal/h
Gas Pressure Requirement 0.7 PSI 5 KPa
Gas Consumption (per ton of alum) 2500 Cf 70 Cm
Furnace Wall Temperature ≤ 86F ≤ 30C
Maximum Temperature 1560F 850C
Dipwell Height 42” 1650 mm
Dipwell Size (W X D) 23.6” x 21.6” 600 x 550 mm
Furnace Size (L x W x H) 148″ x 73″ x 114″ 3750 x 1850 x 2900 mm

Disclaimer: Due to our constant pursuit of technical advancement, all specifications are subject to change without notice.